Specific Fan Power 0.65 W/l/s
Thermal Efficiency to 88%
Accepts 100mm or 125mm Ø ducting
Compatible with auralite status indicator
Quick access filter doors
G3 filters standard, G4 optional
Fully adjustable boost overrun timer 0-60 minutes
Volt free switching control
Intelligent controller, quick and easy to commission
Summer Bypass and humidity controls
SUMMERboost facility
Description
The handing of the unit – left or right hand, refers to the side the ducts to/from atmosphere are positioned. i.e. a left hand (LH) unit will have the intake and exhaust ducts to/from atmosphere positioned on the left hand side of the unit and vice versa for the right hand
Dimensions: 600mm wide x 430mm high (excluding ports) x 285mm deep (295mm with mounting bracket)
Weight: 16kg
Finish: White Paint
Housing: Zintec sheet steel housing, powder coated white
Internals: Expanded polypropylene (EPP)
Heat Exchanger: Polystyrene
Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating
Standard filters: Grade G3 synthetic filters, flame resistance to BS5588
Guarantee period: 3 years (UK only)
Electrical: 230V ~ 50/60Hz, 3A fuse
Installation: Install in accordance with Good Practice, such as the Domestic Ventilation Compliance Guide (England & Wales) and the Residential Ventilation Association recommendations Maintenance: Service and filter clean/replacement subject to local environment - see Product Manual
Brand | TITON CVU CAT 63 |
Delivery | Next Day |